Description:
Liitokala Lii-500 charger has 4 independent charging channels / detection capacity battery / large LCD display / 5V USB output. this charger can charge multiple type of batteries i;e 1.2 V NiMH battery / aa / aaa — lithium-ion battery 26650/22650/26500/18650/18490/17670/17500/17355/16340/14500/10440 simultaneously. It is original product import from china original product links;
Appearance:
1. The charger can only cylindrical lithium ion battery, nickel metal hydride batteries, not rechargeable lithium iron phosphate batteries;
2. Before use, please refer to the instructions carefully, pay attention to the recommendations of the rechargeable battery charging current, do not exceed recommended charging current;
3. Do not use other power adapter;
4. When the charger to charge and discharge may be fever, be careful not to burn.
5. Stop the use, please unplug the power supply, pull out the battery;
6. Only can be used in normal indoor.
7. This product testing data are for reference only, actual situation, please refer to the professional instrument.
Liitokala Lii-500 charger Characteristics:
1. 4 kinds of charging current regulating (300 ma / 500 ma ma / 700/700 ma);
2. To different specifications (18650/26650… / AA/AAA) battery charging at the same time;
3. This charger is bright with a LCD display screen independence, voltage (V), current (mA) time (h). The capacity (mAh) resistance (mR) parameters, E eye know;
4. In CHARGE mode, channel 4 operates independently, allowing selection of various charging currents for lithium-ion and nickel-metal hydride batteries.
5. FAST TEST mode, the four channels can quickly detect battery capacity, regardless of lithium ion battery, nickel metal hydride batteries. Rapid detection of battery capacity process consists of two steps (1, 2 with)
6. NOR the TEST mode, the normal TEST battery capacity process consists of three steps (1 first on a full charge, discharge again 2, 3 again filled), the testing process of battery capacity;
7. CHARGE and FAST TEST. / NOR TEST three patterns can work simultaneously; Independent set charging/rapid detection/normal detection capacity;
8. A variety of protection function: the overcharge, short circuit, temperature, activation function, 0 V voltage, 1.65 V to 1.65 V cannot charge function, bad battery intelligent recognition and reverse connect battery protection.
9. With the function of standard 5 v / 1000 mA USB output: section from 1 to 4 lithium batteries lithium batteries complete USB output, this product nimh batteries can’t take the USB output.
10. Equipped with a special power adapter: dc input voltage: 12 v / 2 a.
Functionality of the buttons of Liitokala Lii-500 charger:
Function 1:
The Liitokala Lii-500 charger has six buttons, MODE selection key (MODE), the current selected key (CURREN), the independent choice and view the data key (1234), concise and easy to use;
Function 2:
Press and hold the MODE key for 3 seconds to switch between CHARGE (rechargeable), FAST TEST, and NOR TEST (capacity) modes. Within 8 seconds, press the corresponding function button to change detection, current, independence, capacity, etc. After 8 seconds, the selected function begins working. During operation, press (1234) to check reference data such as current (mA), capacity (mAh), voltage (V), time (h), and internal resistance (mR).
Function 3:
When the charger plug charger all LCD screen instantly bright, if the battery is not in the will show the Null, if it is a bad battery into will also display Null;
Function 4:
Upon connecting the charger to the battery, the charger measures the battery’s internal resistance in 3 seconds and automatically enters CHARGE mode. The default charging current is 500 mA. Within 8 seconds, you can select a charging current of 300 mA, 500 mA, 700 mA, or 1000 mA using the CURREN key. The system locks your chosen current after 8 seconds. If not set within 8 seconds, the system defaults to 500 mA. Current and other functions cannot be changed afterwards. To change, long-press the mode key
Function 5:
In the charging mode (CHARGE), you have 8 seconds to change the independence or select a different charging current. You can also choose to mix different batteries. There’s a simple light indicator. Within 8 seconds, you can press the corresponding 1234 battery key. Pressing the mode key again will change the settings. If you press the current key, it will change the current detection function, independence, battery type, and capacity. After 8 seconds, the system enters the working state, pay attention to choose the charging current according to battery capacity size, if you don’t need fast charging, suggest using 500 ma charge, this is the most safe;
4. Charging mode, through to 1234 key can switch to check the charge capacity (mAh)/charging time (h)/battery internal resistance (mR)/charging current (mA), voltage (V) 5 units, after the battery is full displays, charging (end);
(a) FAST TEST (rapid capacity TEST mode)
1. When the charger into the battery after turning on the power supply, light 8 seconds press (MODE key MODE), select (FAST TEST capacity FAST detection MODE), and then press the select key CURREN (current) select the desired current, the system will lock in 8 seconds of your choice. Reference table a rapid capacity detection process
The battery is first discharged, and then the battery’s capacity is recorded and inspected during charging. This product is designed to detect battery capacity and has two discharge modes. When you select a charging current of 300 mA or 500 mA, the system automatically defaults to a discharge current of 250 mA. When you select a charging current of 700 mA or 1000 mA, the system automatically defaults to a discharge current of 500 mA. Please note that these settings are important for the accurate detection of battery capacity.
NOR TEST for Liitokala Lii-500 charger:
There are different modes for Liitokala Lii-500 charger
Mode 1:
NOR TEST mode: which is the batteries, the first to record the battery discharge and discharge capacity to TEST battery capacity, after the battery is full of automatically; Refer to table 2 capacity detection process
Mode 2:
When the charger into the battery after turning on the power supply, light according to 8 seconds (MODE key MODE), selected NOR TEST MODE, long press MODE key under any state 2 seconds, can enter NOR TEST MODE;
Mode 3:
Within 8 seconds, use the CURREN key to select a current of 300 mA, 500 mA, or 700 mA. The system locks in your chosen current after 8 seconds. If no current is set within 8 seconds, the system defaults to a charging current of 500 mA. At this time, the system automatically selects a discharge current of 250 mA. If you select a charging current of 700 mA or 1000 mA within 8 seconds, the system automatically selects a discharge current of 500 mA.
Mode 4:
When the battery is fully charged, the system automatically begins discharging at the default current, which is related to the charging current. The system records the discharge data to determine the battery capacity.
Once the screen appears, it signifies the end of the capacity detection mode. The parameters displayed on the LCD at this time are the reference values for the actual capacity of the battery.
Mode 5:
After the capacity to detect patterns, the charger in before the current selected parameters for the battery again, until it is full. Five, the USB 5 v output. USB only move as 5 v output, the output current is 1000 ma, connect the power supply the USB output is invalid. When the battery into the slot of the output USB / 5 v in awake, at this time can be on the 5 v power electronics. Products 4 battery slot, an arbitrary slot are available for USB output, suggested that both slot in the battery. USB 5 V output to only work in 3.7 V lithium battery, nickel metal hydride booster is invalid.
Package Contains :