Contact us :0313-9199444 for any query or issue
Don't know how to place order Click here

SHT2000 thermostat humidity temperature control, hygrometer controller AC 220V 10A incubator

More Views

SHT2000 thermostat humidity temperature control, hygrometer controller AC 220V 10A incubator
5 products sold
PKR 2,550.00

Availability: Out of stock

Cash on Delivery Cash on Delivery option avaliable all over Pakistan

Geniune products guarantee Geniune products guarantee

Buyer payment protection Buyer payment protection, No question ask return policy

Product code : 1474
Product name: Temperature and humidity controller Product
model: SHT2000 Supply
voltage: AC 110 ~ 230V / DC 12-72V
Power supply frequency: 50 / 60Hz
Temperature range: -20 ~ 60 ° C
Range Humidity measurement: 0% ~ 100% RH
Temperature measurement accuracy: 0.3 ° C
Humidity measurement accuracy: 3%
Output control: relay
output Output power: maximum 10 A
Configuration method: start value operating mode is the heating / humidifying mode)
Configuration method: Start value> Stop value (the program automatically determines that the operating
mode is Cooling / dehumidifying mode ) Setting the heating / cooling
Description

Details

SHT2000 thermostat with humidity and temperature control, hygrometer, humidistal controller
AC 110V -220V 10A, Digital display

Product Description:

Specifications:

Product name: Temperature and humidity controller Product
model: SHT2000 Supply
voltage: AC 110 ~ 230V / DC 12-72V
Power supply frequency: 50 / 60Hz
Temperature range: -20 ~ 60 ° C
Range Humidity measurement: 0% ~ 100% RH
Temperature measurement accuracy: 0.3 ° C
Humidity measurement accuracy: 3%
Output control: relay
output Output power: maximum 10 A
Configuration method: start value <stop value (the program automatically determines that the
operating mode is the heating / humidifying mode)
Configuration method: Start value> Stop value (the program automatically determines that the operating
mode is Cooling / dehumidifying mode ) Setting the heating / cooling
mode Setting mode: setting (starting temperature): press and hold the ▲ button to activate the
flashing temperature. Use the ▲ key to set the start temperature value.
Setting (stop temperature): Press and hold the ▼ button to stop the flashing temperature.
▲ ▼ To set the stop temperature value.
Heating use case: control the water heater, heat to 65 ° C to stop, the temperature drops
back to 50 ° C and start to heat again
The first step: Heating mode, start temperature <Stop temperature
Step 2: Press and hold the ▲ button to activate the intermittent temperature.
▲ ▼ To set the starting temperature to 50 ° C.
Step 3: Press and hold the ▼ button to stop the temperature flashing. Set the stop temperature to
65 ° C with the ▲▲ keys and the configuration is complete.
Refrigeration use box: Use on the farm, the fan is ventilated at 26 ° C to stop, the temperature rises to
30 ° C and the ventilation starts again.
The first step: Cooling mode, start temperature> Stop temperature
Step 2: Press and hold the ▲ button to activate the intermittent temperature.
▲ ▼ To set the starting temperature to 30 ° C.
The third step: Press and hold the ▼ button to stop the temperature flashing, set the stop temperature
to 26 ° C with ▲▲, the setting is complete!
Humidification / dehumidification mode setting:
Setting (humidity start): Press and hold the △ key to activate the humidity value flashing. Set the humidity value using the ▽ key. Set [Stop moisture]: Press and hold the △ key to stop flashing the humidity value and set the humidity to pass through the △ ▽ key value.
Humidification example: fresh supermarket humidification, 50% RH control humidifier, which humidifies up to 80% RH to stop humidification.
Step configuration: Step 1: Press and hold the △ button for 3 seconds to activate the flashing humidity value and
set the initial humidity value to 50% RH.
Step 2: Press and hold the ▽ button for 3 seconds to stop flashing the humidity value. Set the value to 80% RH.
After completing the setup, the button will be operated for 5 seconds without returning to the normal viewing state.
Dehumidification example: workshop control exhaust dehumidification system, humidity 70%
RH begins dehumidification, humidity 40% RH prevents dehumidification Step
configuration:
Step 1: Press and hold the △ button for 3 seconds to activate the value of flashing humidity and
set the initial humidity value to 40% RH.
Step 2: Press and hold the ▽ button for 3 seconds to stop the intermittent humidity value, set the value to 70% RH,
the setting is completed, the button does not work for 5 seconds, and automatically returns to the display status normal.

Package Included:
1x SHT2000 thermostat with humidity

Reviews

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.