Contact us :0313-9199444 for any query or issue
Don't know how to place order Click here

VHM-018 DC 5V Real Time Timer Timer Relay Module,Clock Synchronization, Multi-Mode Control

More Views

VHM-018 DC 5V Real Time Timer Timer Relay Module,Clock Synchronization, Multi-Mode Control
19 products sold
PKR 840.00

Availability: In stock

Product code : 1648
VHM-018 DC 5V Real Time Timer, Timer Relay Module, Control, Clock Synchronization, Multi-Mode Control
Real time relay time and clock synchronization time control delay 24H time 5 periods of time
5.0V ~ 60V wide voltage power supply;
A mode can be set for various periods of time, it can reach 5 periods of time;
With buzzer alarm function.
The Monland brand is only authorized to sell Monland branded goods. Buying goods from Monland gives you a great shopping experience. OPE: relay closing time point, CLE: relay off time point
Time period: PE-1 ~ PE-5 5 time periods (OPE to CLE is a time period)
P-1: The relay closes or outputs pulses every day to the OPE time point, and the relay turns off or outputs pulses to the CLE time point.
P-2: set the day, to the OPE time point when the relay closed or output pulse, to the CLE time point when the relay disconnect / or output pulse
P-3: set the date of the month, to the OPE time point when the relay closed or output pulse, to the CLE time point when the relay is off or output pulse
P-4: Set the date 1 to date 2, start every day at the OPE time point, end to the CLE time point, relay action or output pulse
P-5: As with P-4, only the month can not be set
colour:Black
Material:ABS

Cash on Delivery Cash on Delivery option avaliable all over Pakistan

Geniune products guarantee Geniune products guarantee

Buyer payment protection Buyer payment protection, No question ask return policy

Description

Details

VHM-018 DC 5V Real Time Timer, Timer Relay Module, Control, Clock Synchronization, Multi-Mode Control
Description:
Real time relay time and clock synchronization time control delay 24H time 5 periods of time
Featured Products:
5.0V ~ 60V wide voltage power supply;
A mode can be set for various periods of time, it can reach 5 periods of time;
With buzzer alarm function.
Introduction mode:
OPE: Relay close time point, CLE: Relay off time point Time
period: PE-1 ~ PE-5 5 time periods (OPE to CLE is a time period)
----: Function of protection
P-1: The relay closes or pulses every day up to the OPE time point, and the relay turns off or pulses
until the circle time point.
P-2: set the day, up to the OPE time point when the relay has closed or pulse output, to the CLE time
point when the relay disconnects / or the output pulse
P-3: Set the date of the month, up to the OPE time point when the relay closes or exits the pulse,
to the capsule time point when the relay is off or the output pulse
P-4: Set date 1 to date 2, start each day at OPE time point, end with cycle time point,
relay action or output pulse
P-5: as in P-4, only the month cannot be set
First, how to set the time?
At the time of running the interface, press the Down button for a while:
Step 1: Select the time period: PE-1 ~ PE-5 Press up and down to select;
Step 2: Press SET key to select mode: P-1 ~ P-5 (set this time period to corresponding mode) by pressing
up and down keys. ("----" means block this period of time)
Note: Each time period can be repeated from the "----", P-1 ~ P-5 one of the optional; For example,
you can let five time periods at the same time work in P-1 mode, or let time period 1 work in P-1 mode,
time period 2 work in P-2 mode , etc.
Step 3: After finishing the mode selection, press the SET key to enter the time period setting interface,
set the interface to the time period, press the set key to change the parameter, "OPE" Time point start,
"CLE" end point, "dAE" date information;
Step 4: After setting the parameters to exit the setting, press the SET button for 2 seconds to release it,
automatically check whether the parameter setting is legal, legal to save the parameters, back to the
time to run the interface; If the parameter is wrong, "ERR" reminder (for example, Stop time or date
<= start time or date), return to the parameter setting interface;
Additional features: each "time period" can be set individually
In the specific parameter setting interface (after the second step), press the STOP button to
switch the output mode:
OUT1: the start time point turns on the relay, the end time is off.
OUT2: outputs 1S press to start or end the time
In the specific parameter setting interface (after the second step), press the STOP button for a
while to switch the call mode:
BLL0: Ring disable
BLL1: Ring allow
Note: When the bell rings, press any button to stop the ring
Expansion stop key function:
Relay enable:
1. On: activate relay;
2. Off: Do not turn on the relay, it is always off;
Press the stop button on the time display interface to switch between on and off, the current status
will flash, and then return to the main interface.
(This function is the emergency stop function, press once to close the closed relay)
After broadcasting is disabled, the product can be used as an alarm clock.
Sleep:
1. CP sleep mode: within five minutes, without any operation, the digital tube automatically turns off
the screen, the normal operation of the program;
2. Od Normal mode: the digital tube is always open;
Press the stop button for a while after 2 seconds to release it, to achieve CP and od status of the switch,
the current status will flash and then return to the main interface.
Package Included:
1pc * VHM-018 DC 5V Timer Relay Module

Reviews

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.