Product Description:
4 In 1 100A DC6.5=100V Digital Power Meter Monitor Energy Voltmeter Ammeter + 100A Shunt
Function:
1. Measurement function of electrical parameters (voltage, current, power, energy).
2. The voltage alarm function (alarm thresholds for overvoltage, backlight and voltage flicker tips).
3. Clear power button function.
4. Power off data storage function.
5. large screen LCD display full display function (display voltage, current, power, energy).
6. backlight
B. Display and key
I screen interface
Show voltage, current, power, power parameters of large LCD display simultaneously.
II screen format
1. Power: measuring range 0-10 kW
1 kW display format at 0.0 = 999.9 W;
From the 1kW 1000 = 9999 W. screen format.
2. Power: measurement range 0 9999kWh
10 KWh within the screen format 0 = 99wh;
Display format greater than 10kWh 10 = 99kwh;
3. Voltage: test range 6.5-100V
Screen format 6.50 = 99.99 V
4. Current: test range 0 = 100A
Screen format 0.00 to 99.99.
5 V oltage accuracy: +/- 1%
III button
1. backlight control
By shortly pressing the button to turn the backlight on or off, the backlight status is automatically stored.
2. Clean energy
Step 1: Press the button until the feed area shows the character “CLr”, then release the button;
Step 2: At this point in the flashing power consumption indicating that the current state is clean, if you press the button
again shortly, the consumption data is deleted and stop flashing;
Step 3: If no key is pressed within five seconds, this means that the power does not clean the data and leaves free.
3. The voltage alarm value
Step 1: press the button until the feed area shows the “SET” character and then release the button
Step 2: After entering this state, the high pressure area voltage shows the current alarm value,
the current area shows the current low pressure alarm value, and the least important bit starts to flash,
then you can press the button through the + 1 short bit, when there is no button operation in more than three seconds,
the automatic adjustment of the high pressure position switch to the low pressure alarm value has a value,
a total of six, The voltage range alarm threshold set for 6.5-99.9V
Step 3: after the configuration, press the button until the display shows the character “PASS” indicates that the
configuration is correct and automatically exits the setting mode?
4 Range Selector
Step 1: Press the button until the feed area shows the character “Curr”, then release the button;
Step 2: At this point, the current area shows “100 A”, short press button between “100 A” and “50 A” switch, to represent
the external current range is A / 75mV or / 75mV, attention, The table can only use these two specifications.
Step 3: Press the button until you exit the configuration mode or the key will not be automatically saved after
3 seconds and exit the configuration mode.
Notes:
1. This module is suitable for indoor use, not outdoors.
2. The applied load cannot exceed the nominal voltage and current.
3. The wiring order cannot be wrong.
Specifications
1. Operating voltage: 6.5 = 100VDC
2. test voltage: 6.5 = 100VDC
3. Rated power: 10000 a / W
4. measurement accuracy: 1.0
Package include:
1x DC 100A Digital Power Meter Monitor
1x 100A Shunts?With English manual?